Products
Suppliers
Sign in
Register
Xi'an Xu&Hui Electromechanical Technology Co., Ltd.
Xi'an Xu&Hui Electromechanical Technology Co., Ltd.
Manufacturer from China
Verified Supplier
1 Years
Home
Products Catalog
Company Profile
Quality Control
Contact Us
Request a Quota
English
Français
Русский язык
Español
日本語
Português
TDR Cable Fault Locator (17)
Cable Fault Locator (10)
Cable Fault Pinpointer (9)
Cable Route Tracer (10)
Transformer Tester (71)
CT PT Analyzer (3)
High Voltage Surge Generator (12)
Cable Sheath Fault Locator (3)
Circuit Breaker Analyzer (21)
Cable Identifier (2)
Cable Spiker (2)
Relay Protection Tester (18)
Cable Test Van (1)
Ground Tester (9)
AC DC Hipot Tester (27)
Cable Fault Simulation System (1)
Digital Burn-Through bridge (2)
DC High voltage Power Supply (1)
Energy Storage Capacitor (1)
Portable Cable Fault Location System (14)
Home
/
Products
/
Transformer Tester
/
350mm*280mm*170mm Insulating Oil Gas Analysis Gas Analyzer with Flame Ionization Detector
Product Categories
TDR Cable Fault Locator
[17]
Cable Fault Locator
[10]
Cable Fault Pinpointer
[9]
Cable Route Tracer
[10]
Transformer Tester
[71]
CT PT Analyzer
[3]
High Voltage Surge Generator
[12]
Cable Sheath Fault Locator
[3]
Circuit Breaker Analyzer
[21]
Cable Identifier
[2]
Cable Spiker
[2]
Relay Protection Tester
[18]
Cable Test Van
[1]
Ground Tester
[9]
AC DC Hipot Tester
[27]
Cable Fault Simulation System
[1]
Digital Burn-Through bridge
[2]
DC High voltage Power Supply
[1]
Energy Storage Capacitor
[1]
Portable Cable Fault Location System
[14]
Contact Now
Xi'an Xu&Hui Electromechanical Technology Co., Ltd.
Visit Website
Country/Region:
china
Contact Person:
MissSerena
View Contact Details
Contact Now
350mm*280mm*170mm Insulating Oil Gas Analysis Gas Analyzer with Flame Ionization Detector
Ask Latest Price
Certification :
CE, ISO
Brand Name :
XZH TEST
Model Number :
XHSP1700
Place of Origin :
Xi'an, Shaanxi, China
MOQ :
1 unit
Payment Terms :
T/T
Supply Ability :
1000pieces/Year
Delivery Time :
5-8 days
Packaging Details :
wooden packaging
Model NO. :
XHSP1700
Test Region :
Forming Cable
Cable Type :
CAT3
Customized :
Customized
Color :
Black
Test Frequency :
128Hz/111Hz/105Hz/94Hz(Afc)
Resolution :
0.5m
Transport Package :
Wooden Box Filled with Foam Inside
Specification :
350mm*280mm*170mm
Origin :
China Xi′an
HS Code :
8543201000
Customization :
Available
After-sales Service :
Warranty Certificate
Warranty :
12 Months
more
Contact Now
Add to Cart
Find Similar Videos
View Product Description
Transformer oil gas tester/gas chromatograph analyzer
Main technical datas
• operating display: 5.7 inch periodic lattice Chinesize color liquid crystal (can be equipped with touch screen)
• temperature control area: 6 ways • temperature: room temperature above 5 ºC ~ 400 ºC, incremental:1 ºC, accuracy :± 0.1 ºC
• temperature-programmed order: 16 order
• Temperature program rate: 0.1 ~ 39 ºC /min (common type); 0.1 ~ 80 ºC /min (high speed)
• the gas control: optional pressure flow control mode of the mechanical valve control mode, electronic
• gas pressure, flow measurement: pointer type pressure meter or electronic pressure, flow pattern
• all electronic gas pressure, flow measurement system The single module maximum measuring way: 16 Range: 0 ~ 0.3MPa (pressure); 0 ~ 500sccm (flow) Resolution: 0.01kPa (pressure); 0.01sccm (flow)
• EPC, EFC work mode: 3kinds:constant current mode, constant voltage mode, bypass mode
• EPC, EFC working gas: 4kinds:nitrogen, air, hydrogen, helium, argon
• EPC, EFC L: 4 order EPC, EFC: pressure control range: 0 ~ 0.6MPa; flow rate of 0 ~ 100sccm or 0 ~ 500sccm (air);
• EPC, EFC control precision pressure 0.01kPa; flow rate: 0.01sccm;
• external events: 4 road, 4 road; auxiliary control output
• injector types: packed column sample, the capillary inlet, six valve gas sampling, automatic headspace sampling.
• detector number: 3 (up); FID, TCD, ECD, FPD and NPD.
• start sampling: manual, automatic optional
• communication interface: Ethernet: IEEE802.3
Detector technology index
Hydrogen flame ionization detector (FID)
•The limit of detection: ≤ 1×10-11g/s (sixteen alkyl);
• baseline noise: ≤5×10-14A
• baseline drift: ≤1×10-13A/30min
• linear range:≥106
Thermal conductivity detector (TCD)
• sensitivity: S ≥ 2500mV•ml/mg (sixteen alkyl) (1, 2, 4, 8 times enlarged ,optional.)
• baseline noise: ≤ 20 μ V
• baseline drift: ≤ 30 μ V/30min
• linear range:≥104
Electron capture detector (ECD)
•The limit of detection: ≤ 1×10-13g/ml(C 666 - isooctane solution)
• baseline noise: ≤ 0.03mV
• baseline drift: ≤ 0.2mV/30min
• linear range: 103
• source: 63Ni
Flame photometric detector (FPD)
•The limit of detection: (S) ≤5×10-11g/s, (P) ≤1×10-12g/s; methyl parathion - ethanol solution)
• baseline noise: ≤ 3×10-13A
• baseline drift: ≤2×10-12A/30min
• linear range: To sulfur≥102, To P ≥103
Inquiry Cart
0
Select All
Contact Now